* Ideal Transformer Subcircuit Parameters |
|
* RATIO1 = turns ratio (= secondary1/primary) |
|
* RATIO2 = turns ratio (= secondary2/primary) |
|
* |
|
* Ideal Transformer with three windings |
|
* jjt 18/12/00: created using IDEAL4W (created by dw, 18/12/2000) as a template. |
|
* Connections: |
|
* Pri+ |
|
* | Pri- |
|
* | | Sec1+ |
|
* | | | Sec1- |
|
* | | | | Sec2+ |
|
* | | | | | Sec2- |
|
* | | | | | | |
|
* | | | | | | |
|
* | | | | | | |
|
.SUBCKT IDEAL3W 1 2 3 4 5 6 PARAMS: RATIO1=1 RATIO2=1 |
|
BP 1 2 I=( -I(BS1)*{RATIO1} - I(BS2)*{RATIO2} ) |
|
BS1 3 4 V=( V(1,2)*{RATIO1} ) |
|
BS2 5 6 V=( V(1,2)*{RATIO2} ) |
|
.ENDS IDEAL3W |