*Transformer Subcircuit Parameters |
|
*RATIO = Turns ratio= Secondary/Primary |
|
*RP = Primary DC resistance |
|
*RS = Secondary DC resistance |
|
*LEAK = Leakage inductance |
|
*MAG = Magnetizing inductance |
|
|
|
*Generic Transformer |
|
*dw: 2-8-99 corrected VISRC polarity and FCTRL configuration |
|
*Connections: |
|
* Pri+ |
|
* | Pri- |
|
* | | Sec+ |
|
* | | | Sec- |
|
* | | | | |
|
.SUBCKT TRANS 1 2 3 4 PARAMS: RATIO=1 RP=0.1 RS=0.1 LEAK=1u MAG=1k |
|
VISRC 4 9 0V |
|
FCTRL 5 2 VISRC {RATIO} |
|
EVCVS 8 9 5 2 {RATIO} |
|
RPRI 1 7 {RP} |
|
RSEC 8 3 {RS} |
|
LLEAK 7 5 {LEAK} |
|
LMAGNET 2 5 {MAG} |
|
.ENDS TRANS |