*DPST Relay Subcircuit Parameters |
|
*PULLIN = Pull in voltage |
|
*DROPOFF = Drop off voltage |
|
*CONTACT = Contact resistance |
|
*RESISTANCE = Coil resistance |
|
*INDUCTANCE = Coil Inductance |
|
* jjt 15/6/2002: changed DPDT model to DPST. |
|
* |
|
*Generic DPST Relay |
|
*Connections: NO_A1 |
|
* | NO_A2 |
|
* | | NO_B1 |
|
* | | | NO_B2 |
|
* | | | | T1 |
|
* | | | | | T2 |
|
* | | | | | | |
|
* | | | | | | |
|
* | | | | | | |
|
* | | | | | | |
|
.SUBCKT DPSTRELAY 1 2 3 10 4 5 |
|
+ PARAMS: PULLIN=4 DROPOFF=0.1 CONTACT=1m RESISTANCE=500 INDUCTANCE=10m |
|
L1 4 6 {(INDUCTANCE/2)} |
|
L2 5 7 {(INDUCTANCE/2)} |
|
R1 6 7 {RESISTANCE} |
|
* |
|
BNO1 8 0 V={PULLIN}-abs(v(6,7)) |
|
SW1 1 2 8 0 SWNO OFF |
|
* |
|
BNO2 9 0 V={PULLIN}-abs(v(6,7)) |
|
SW2 3 10 9 0 SWNO OFF |
|
* |
|
.MODEL SWNO SW(VT={(PULLIN*0.98)} RON={CONTACT} ) |
|
.ENDS DPSTRELAY |