*Transformer Subcircuit Parameters *RATIO1 = Turns ratio= Secondary1/Primary *RATIO2 = Turns ratio= Secondary2/Primary *RATIO3 = Turns ratio= Secondary3/Primary *RPRI = Primary DC resistance *R2D = Secondary1 leakage resistance referred to the primary side *R3D = Secondary2 leakage resistance referred to the primary side *R4D = Secondary3 leakage resistance referred to the primary side *L1 = Primary Leakage inductance *XM = Magnetizing Reactance *RCORE = Core Loss Resistance *X2D = Secondary1 Leakage Reactance referred to the primary side *X3D = Secondary2 Leakage Reactance referred to the primary side *X4D = Secondary3 Leakage Reactance referred to the primary side *Non-ideal 4-winding Transformer *jjt created 17/1/2001. *jjt 18/1/2002: deleted a comment line (of default values) which lacked the asterisk, changed the parameter comments * to be consistent with the parameters to avoid possible confusion. *Connections: * Pri+ * | Pri- * | | Sec1+ * | | | Sec1- * | | | | Sec2+ * | | | | | Sec2- * | | | | | | Sec3+ * | | | | | | | Sec3- * | | | | | | | | * | | | | | | | | .SUBCKT NI4WTRANS 1 2 3 4 5 6 7 8 PARAMS: RATIO1=1 RATIO2=1 RATIO3=1 RPRI=0.1 R2D=0.1 R3D=0.1 R4D=0.1 L1=1U + X2D=1u X3D=1u X4D=1u XM=1k RCORE=1Meg VISRC1 4 13 0V VISRC2 6 16 0V VISRC3 8 19 0V FCTRL1 12 2 VISRC1 {RATIO1} FCTRL2 15 2 VISRC2 {RATIO2} FCTRL3 18 2 VISRC3 {RATIO3} EVCVS1 3 13 12 2 {RATIO1} EVCVS2 5 16 15 2 {RATIO2} EVCVS3 7 19 18 2 {RATIO3} RRPRI 1 10 {RPRI} RR2D 11 12 {R2D} RR3D 14 15 {R3D} RR4D 17 18 {R4D} LL1 10 9 {L1} LX2D 9 11 {X2D} LX3D 9 14 {X3D} LX4D 9 17 {X4D} LXM 9 2 {XM} RRCORE 9 2 {RCORE} .ENDS NI4WTRANS